Opacity QAL1 Approved Particulate CEM STACK 710
QAL1 approved particulate CEM which meets US EPA PS-1 requirements for Opacity monitoring from combustion stacks
Robust multi corner cube reflector provides truer reflection of transmitted light compared to traditional “mirror type” reflectors providing greater confidence in measurement
Features & Benefits
- Outstanding reliability with no continuously moving parts
- Automatic in-situ zero and span checking with built-in calibration audit and zero drift correction
- Dual light source, with patented Flood LED source provides robust check of the detectors
- and minimises effects of temperature instability
Main applications
- Stacks after bag filters, cartridge filters, cyclones, electrostatic precipitators, no filtration
- Non-condensing / dry flue gases
Typical Applications:
- Incineration
- Metals (eg Steel/Aluminium)
- Minerals (eg Cement/Gypsum)
- Chemicals (eg Refinery / Rubber)
- Power Generation Plant (eg Coal/Biomass)
Technical Specifications |
Measured parameters |
Dust |
Technology |
Opacity |
Measurement/Monitoring capability |
0-100%* |
Stack/Duct diameter suitability |
up to 10m |
Flue gas temperature |
up to 600°C |
Baghouse |
YES |
Cartridge Filter |
/ |
Ceramic Filter |
/ |
Coalescent Filter |
/ |
Cyclone |
/ |
Electrostatic Precipitator (ESP) |
YES |
Wet Electrostatic Precipitator (WESP) |
/ |
Wet Scrubber |
/ |
Sensor variants |
Cast aluminium, epoxy coated |
QA checks |
YES |
*Application dependant
Technical data |
Measurement capability |
0 – 100% (opacity); 0-1000 mg/m3 (concentration) |
Sensor Variants |
cast aluminium, epoxy coated |
Stack Temperature Ranges |
up to 600°C |
Functionality and QA Checks |
Automatic zero and span; automatic correction for zero drift |
Interface |
– Available as standalone sensor pair (no controller) or with either standard control unit (Interface module) for single stack or with ProController for multi-sensor networks – Available with standard control unit (Interface module) for single stack or with ProController for multi-sensor networks |
On-board data logging (control unit only) |
User configurable Long term, Short term or Pulse logging |
Output |
RS232, RS485 (Modbus), Ethernet Digital Alarm and 4/20mA (number of outputs dependant on system configuration (with or without controller) |
Air Purge |
blower required |
Enclosure Protection Rating |
IP65 |
Approvals & Certifications
- TÜV (UBA) certified to EN15267-3
- QAL1 as defined by EN14181
- QAL3 compliance to EN14181
- US EPA PS-1 compliant
- GOST Approved
Documentation
envea_stack-710_qal1-opacity-monitoring_en
envea_catalogue_cems_emission-monitoring_en
envea_technical-services-datasheet_en